The latest salt spray test chamber GBT10125-2012 standard test report

12. Test Report

The test report must clearly state the evaluation criteria applied and the results obtained. If applicable, it should include test results for each individual sample, average results for groups of identical samples, or photographs of the samples to support the findings.

Specific details that should be included in the report are as follows:

a) The standard number and any relevant referenced standards;

b) The type of salt and water used during the test;

c) A detailed description of the material or product being tested;

d) The dimensions, shape, surface area, and condition of the sample;

e) Preparation steps for the sample, including cleaning before testing and protection of edges or other sensitive areas;

f) Description of the coating layer and any surface treatments present;

g) The total number of samples tested;

h) Method of cleaning the sample after the test, if applicable, along with any weight loss caused by this process;

i) The angle at which the samples were placed within the chamber;

j) Frequency and number of times the samples were moved or adjusted;

k) The duration of the test cycle and results from intermediate inspections;

l) Performance of a reference sample placed specifically in the salt spray chamber to verify test conditions;

m) The temperature maintained during the test;

n) The rate at which salt spray settled on the samples;

o) The pH of both the test solution and the collected solution;

p) The density of the collected liquid;

q) Corrosion rate of the reference sample, expressed in mass loss per square meter (g/m²);

r) Any unexpected events that may have affected the test outcomes;

s) The interval between inspections during the test period.

The test report must follow the requirements outlined in GBT10125-2012, which provides guidelines for conducting and documenting salt spray tests. This ensures consistency and reliability in the reporting process. It is important that all data is recorded accurately and transparently to allow for proper evaluation and comparison of results across different tests.