How to use pH composite electrode correctly

(1) There should be no air bubbles at the front end of the bulb. If there is a bubble, apply it.
(2) After the electrode is taken out of the soaking bottle, it should be shaken and dried in deionized water. Do not wipe the bulb with a paper towel. Otherwise, the electrostatic induction charge will be transferred to the glass film, which will prolong the potential stabilization time. A better method is Rinse the electrode with the solution being tested.
(3) After the pH composite electrode is inserted into the solution to be tested, it should be shaken a few times and then placed still, which will accelerate the response of the electrode. Especially when using a molded-shell pH composite electrode, the stirring sloshing is more severe, because there is a small cavity between the bulb and the molded shell. After the electrode is immersed in the solution, sometimes the gas in the cavity is too late to be eliminated, so that the bubble is generated. The bubble or liquid junction is in poor contact with the solution, so it is necessary to stir vigorously to remove air bubbles.
(4) After testing in a viscous sample, the electrode must be rinsed repeatedly with deionized water several times to remove the sample adhering to the glass film. Sometimes it is necessary to wash the sample with other reagents, then wash the solvent with water and immerse it in the soak solution to activate.
(5) Avoid contact with strong acid and alkali or corrosive solutions. If testing such solutions, minimize the immersion time and carefully clean them after use.
(6) Avoid use in dehydrating media such as absolute ethanol or concentrated sulfuric acid, which will damage the hydrated gel layer on the surface of the bulb.
The shell material of the molded-shell pH composite electrode is polycarbonate material (PC). PC plastic will dissolve in some solvents, such as carbon tetrachloride, trichloroethylene, tetrahydrofuran, etc. If the test contains the above solvent, it will be damaged. For the electrode housing, the pH composite electrode of the glass housing should be used instead.

Medical Hospital Bed 5 functions Electric Hospital Bed

 

Features: 

1. With easily operated touching switch.

2. [Reset"Function,bed can back to "Zero"position quickly.
3. Backup Battery,for emergency power failure.
4. Central locking castors controlled by electric.
5. Insert touching switch in the 2pcs side rail at the head side,also a touching switch at the foot board .
6. Detachable head& foot board in PP plastics .
7. foldable PP side rail foldable install on bed both side,controlled by gas spring.
8. Bed board with soft connection,make the bending of the bed board more smooth to let the patient feel more comfortable.
9. IV pole mount bracket ,at 4corners of the bed frame.  good price

Hospital Bed

Technical datas:

Material

Steel framework ,ABS&PP for plastic part

Dimension

2330mm(L)×1050mm(W)×430-750mm

Bed Board 

1955mm×900mm

Back-rest

0-75°±5

Foot-rest

0-45°±5

Hi-Low

750mm-430mm

Trend & Rev Trend

10°

Insurance

12 mouths

Net weight

148kg

Load capacity

<200kg

Castor

150mm swivel(Central Locking)




Hospital Bed

Hospital Bed,Nursing Hospital Bed,Hospital Medical Sick Beds,Medical Hospital Bed

Shandong qufu healthyou Medical Technology co.,Ltd , https://www.kangerjianmedical.com