Rat Interleukin-1a (IL-1a) ELISA Kit

Rat Interleukin-1a (IL-1a) ELISA Kit

(Used in serum, plasma, cell culture supernatant and other biological fluids)

principle

This experiment uses the double antibody sandwich ABC-ELISA method. The anti-rat IL-1a monoclonal antibody was coated on the enzyme plate. The IL-1a in the standard and the sample was combined with the monoclonal antibody. Biotinylated anti-rat IL-1a was added to form an immune complex and connected to the plate. On the top, the horseradish peroxidase-labeled Streptavidin is combined with biotin, the substrate working solution is added, the blue is added, and finally the stop solution sulfuric acid is added. The OD value is measured at 450nm. Draw a standard curve to find the concentration of IL-1a in the specimen.

Kit composition (stored at 2-8 ° C)

Coated Wells

96 wells

Enzyme Conjugate

12ml

10 × Sample Buffer

12ml

20 × concentrated washing solution (Wash Buffer)

50ml

Standards (Standards): 30ng / bottle

2 bottles

Substrate working solution (TMB Solution)

12ml

The first antibody working solution (Biotinylated Antibody)

12ml

Stop Solution (Stop Solution)

12ml

Prepare reagents and collect blood samples

1. Collect specimens: serum, plasma (EDTA, citrate, heparin anticoagulation), cell culture supernatant, tissue homogenate, etc. as soon as possible, stored at 2-8 ℃ for 48 hours; longer time must be frozen (-20 ℃ Or -70 ℃), avoid repeated freezing and thawing.

2. Preparation of standard solution: add 3ml of distilled water to mix well before use to make a 10ng / ml solution. Set 8 standard tubes, add 900ul of sample dilution in the first tube, and 500ul of sample dilution in the second to eighth tubes. Add 100 ul of standard solution of 10 ng / ml to the first tube and mix it. Then aspirate 500 ul with the sampler and move to the second tube. Repeat the dilution in this manner repeatedly, draw 500ul from the seventh tube and discard it. The eighth tube is a blank control.

3. The 10 × specimen dilution is diluted 1:10 with distilled water (example: 1ml concentrated dilution + 9ml distilled water).

4. Washing solution: 1:20 dilution with redistilled water (example: 1ml concentrated washing solution is added with 19ml of redistilled water)

Testing procedures

1. Add sample: add 100ul of standard or sample to be tested to each well, mix the reaction plate thoroughly and place at 37 ℃ for 120 minutes.

2. Wash the plate: wash the reaction plate 4-6 times with the washing solution, and print it on the filter paper.

3. Add 100ul of the first antibody working solution to each well. The reaction plate was mixed thoroughly and then placed at 37 ° C for 60 minutes.

4. Wash board: same as above.

5. Add 100ul of enzyme-labeled antibody working solution to each well. Place the reaction plate at 37 ° C for 30 minutes.

6. Wash board: same as above.

7. Add 100ul of substrate working solution to each well, and place in a dark place at 37 ℃ for 15 minutes.

8. Add 100ul of stop solution to each well and mix well.

9. Measure absorbance at 450nm with a microplate reader within 30 minutes.

Result calculation and judgment

1. All OD values ​​should be calculated after subtracting the blank value.

2. With the standard products 1000, 500, 250, 125, 62.5, 31.2, 15.6, 0 pg / ml as the abscissa, and the OD value as the ordinate, draw a graph on the graph paper and draw a standard curve.

3. According to the OD value of the sample, find the corresponding IL-1a content on the graph.

Kit performance

1. Sensitivity: The minimum detection concentration of IL-1a is less than 8pg / ml.

2. Specificity: simultaneous detection of recombinant or natural rat IL-1a. Does not cross-react with other cytokines in rats.

3. Repeatability: The coefficient of variation within the board and the board is less than 10%.

Precautions

1. The above standard holes and samples to be tested are recommended to be re-holes, and the standard curve should be made at the same time for each measurement.

2. The washing process is critical. Insufficient washing will lead to an increase in accuracy error and OD value.

3. After opening the slats, the remaining slats should be sealed again to keep the slats dry.

4. This kit should be stored in a 4oC refrigerator.

5. This kit is for scientific research only, not for clinical diagnosis!

Custom Tube Slide
Here at outdoor-playground.com, we can design and produce the Custom Tube Slide of your dreams! Whether for an outdoor setting, as a stand-alone slide, as a pool slide, as replacement slide for a public playground, or a fast and fun way for your kids to get down to the living room, we have the expertise to accomplish the project. The slide entrance panel and all tube plastics, joint pre-assembly, tube saddles, and piping support hardware are included - everything you need for installation.
Pre-Designed Dry Slides
Choose below from several of the pre-designed Spiral Tube Slides pictured, ranging from a 7 ft deck height all the way to 16 ft. Certain variations for these slides are available at no additional cost, including slide direction (right or left turning), indoor or outdoor mounting, and there are a huge number of roto-molded colors to choose from! While our pre-designed slides are intended for dry use and not to be water-assisted pool slides, we can design and quote a slide made specifically for use with water.

To see complete roto-molded plastic specifications, color options, and other helpful information about ordering these slides, visit our Custom Tube Slide Information page.
Custom Designed Dry & Pool Slides
Should you require a more customized solution, we invite you to submit a no obligation Custom Tube Slide Design Request. Within approximately 5 to 7 business days you will receive both a .pdf of the ACAD design and a price quote including shipping cost to the designated location and – if ordered – the cost of professional installation.

Custom Tube Slide

Indoor Tube Slide,Custom Tube Slide,Playstar Tube Slide,Kids Custom Tube Slide

Shenyang Golden Childhood playground equipment CO.,LTD , https://www.outdoor-playground.com