Maintenance and repair of constant temperature water bath

Shanghai Xinzhuang Instrument Co., Ltd. develops the brand water bath of Xinzhuang (LNB) brand, which is energy-saving and environmentally friendly and leading domestically. Professional manufacturing is more secure and affordable.
Cautions 1. The case must be effectively grounded.
2. Do not turn on the power before adding water to prevent the hot wire of the electric heating tube from burning.
3. Do not open the right side of the board if it is not necessary for safety.
Maintenance and repair:
1. Turn off the power after use.
2. The inside and outside of the box should be kept clean and tidy.
3. If the indicator light is not lit, first turn off the power, unplug the plug and unpack the right side of the board. If the fuse or the indicator bulb is damaged, replace it with the same specifications.
4. If the constant temperature control fails, the sensor on the controller is malfunctioning. After the exchange, the 9 constant temperature water bath can be used. Common faults and treatment methods. The common faults of the water bath are:
(1) The display is normal, the setting is normal, and heating is not possible.
The fault solution method: turn on the power, turn on the power switch, adjust the set temperature higher than the actual measured temperature, check whether the temperature controller has an output indication, and then measure whether the heating tube has a voltage input, and if there is a heating tube, the replacement is Yes, there is no voltage input to the heating tube, and most of the relays are faulty. If the temperature controller does not have a voltage output indication, it is recommended to replace the temperature controller.
(2) The temperature controller displays LLL or 999 (the parameters are different depending on the manufacturer)
The fault is that the temperature sensor is open or shorted, and the sensor can be replaced.
(3) The temperature is not controlled by the control relay or the sensor is damp:
1. Clean the instrument immediately after each use. Put the water in the water bath clean, brush off the coarse material in the water bath with a brush, and remove the pot. Wipe the inner and outer surfaces of the water bath with a soft cloth and dry with a cleaning cloth.
2. The inner surface of the device should be free of water, and the outer surface of the device should be bright and tidy, without smudging.
3. When the water bath is in use, it must be grounded reliably and the water should not overflow into the control box.
4. Do not water or the water level in the water bath is lower than the electric heating tube to prevent the electric heating tube from being damaged.
5. Perform maintenance inspection of the instrument once a month and fill in the maintenance record in time.
Shanghai Xinzhuang Instrument Co., Ltd. is a company specializing in R&D, production and sales of low temperature experimental equipment and ultrasonic equipment. The company has professional temperature control technicians and advanced production equipment; perfect production process; to ensure product quality; to achieve safe production. Strive for beautiful, practical, stable and cost-effective products, and strive to save more experimental space for our customers. We will continue to provide you with safe, stable and high-performance experimental equipment to make your experiment process easier. Free delivery throughout the country. Reasonable price, quality three guarantees, lifetime maintenance, providing customers with fast, professional, high-quality systematic services, with the tenet of "customer first, quality first, reputation first", we sincerely welcome new and old customers. Customer patronage, common development, create brilliant!
Shanghai Xinzhuang professional production of experimental equipment, technology leadership, quality assurance, welcome your advice http://

4 Layers Rack

shelves, steel frame shelves, book shelves for home, shoes shelves, 4 layers rack

Dongguan Smart Furniture Co.,Ltd , https://www.smtfurniture.com